Search results for "Micellar liquid chromatography"
showing 10 items of 108 documents
Development of a method to determine axitinib, lapatinib and afatinib in plasma by micellar liquid chromatography and validation by the European Medi…
2017
A method based on micellar liquid chromatography to quantify the tyrosine kinase inhibitors axitinib, lapatinib and afatinib in plasma is reported. The sample pretreatment was a simple 1/5-dilution in a pure micellar solution, filtration and direct injection, without requiring extraction or purification steps. The three drugs were resolved from the matrix in 17 min, using an aqueous solution of 0.07 M sodium dodecyl sulfate – 6.0% 1-pentanol, buffered at pH 7 with 0.01 M phosphate salt as mobile phase, running under isocratic mode at 1 mL/min through a C18 column. The detection was performed by absorbance at 260 nm. An accurate mathematical relationship was established between the retention…
Isocratic and gradient elution in micellar liquid chromatography with Brij-35
2015
Polyoxyethylene(23)lauryl ether (known as Brij-35) is a nonionic surfactant, which has been considered as an alternative to the extensively used in micellar liquid chromatography anionic surfactant sodium lauryl (dodecyl) sulfate, for the analysis of drugs and other types of compounds. Brij-35 is the most suitable nonionic surfactant for micellar liquid chromatography, owing to its commercial availability, low cost, low toxicity, high cloud temperature, and low background absorbance. However, it has had minor use. In this work, we gather and discuss some results obtained in our laboratory with several β-blockers, sulfonamides, and flavonoids, concerning the use of Brij-35 as mobile phase mo…
Micellar liquid chromatography for prediction of drug transport.
2000
Abstract The vast majority of well absorbed drugs are transported passively across the cell membranes. Physicochemical descriptors of drug molecules that are believed to influence transcellular transport are routinely used to predict drug absorption by means of complex mathematical models. In this paper, a new in vitro method, based on the retention data in micellar liquid chromatography (MLC), is validated for the prediction of passive drug absorption. The retention of a heterogeneous drugs set in MLC using Brij 35 as surfactant in the mobile phase is compared with the retention data reported in literature obtained in red cell membrane lipid liposomes, human red cell membranes vesicles (ve…
Performance of different C18 columns in reversed-phase liquid chromatography with hydro-organic and micellar-organic mobile phases
2014
Column selection in reversed-phase liquid chromatography (RPLC) can become a challenge if the target compounds interact with the silica-based packing. One of such interactions is the attraction of cationic solutes to the free silanols in silica-based columns, which is a slow sorption-desorption interaction process that gives rise to tailed and broad peaks. The effect of silanols is minimised by the addition of a competing agent in the mobile phase, such as the anionic surfactant sodium dodecyl sulphate (SDS). In micellar-organic RPLC, the adsorption of an approximately fixed amount of SDS monomers gives rise to a stable modified stationary phase, with properties remarkably different from th…
Peak half-width plots to study the effect of organic solvents on the peak performance of basic drugs in micellar liquid chromatography.
2009
The addition of the anionic surfactant sodium dodecyl sulphate (SDS) to hydro-organic mixtures of methanol, ethanol, propanol or acetonitrile with water yielded enhanced peak shape (i.e. increased efficiencies and symmetrical peaks) for a group of basic drugs (β-blockers) chromatographed with a Kromasil C18 column. The effect can be explained by the thin layer of surfactant associated to the hydrocarbon chain on the stationary phase in the presence of the organic solvents, which covers the free silanols on the siliceous support avoiding their interaction with the cationic basic drugs. These instead interact with the anionic head of the surfactant increasing their retention and allowing a mo…
Interpretive search of optimal isocratic and gradient separations in micellar liquid chromatography in extended organic solvent domains
2020
Abstract Micellar liquid chromatography (MLC) is a reversed-phase mode with mobile phases containing an organic solvent and a micellised surfactant. Most procedures developed in MLC are implemented in the isocratic mode, since the general elution problem in chromatography is less troublesome. However, gradient elution may be still useful in MLC to analyse mixtures of compounds within a wide range of polarities, in shorter times. MLC using gradients is attractive to determine by direct injection moderate to low polar compounds in physiological samples. In these analyses, the use of initial micellar conditions (isocratic or gradient) with a fixed amount of surfactant above the critical micell…
Micellar Liquid Chromatography: A Worthy Technique for the Determination of β-Antagonists in Urine Samples
1998
Several beta-antagonists (acebutolol, atenolol, celiprolol, labetalol, metoprolol, nadolol, propranolol) were determined in urine samples with fluorometric detection after direct injection, in less than 15 min, with a micellar mobile phase of 0.1 M sodium dodecyl sulfate (SDS), 15% propanol, and 1% triethylamine at pH 3. The limits of detection (38 criterion) were usually between 3 and 30 ng/mL. The addition of propanol and triethylamine and the reduction of the pH of the mobile phase improved the efficiency of the chromatographic peaks that was rather low in pure micellar eluents. The selection of the composition of the mobile phase was easily performed through the use of an interpretive p…
Determination of barbiturates in urine by micellar liquid chromatography and direct injection of sample.
2000
Abstract A liquid chromatographic procedure for the determination of six barbiturates (barbital, diallyl barbituric acid, phenobarbital, butabarbital, amobarbital and pentobarbital) in urine samples is described. The proposed system uses a Spherisorb octadecyl-silane ODS-2 C 18 analytical column and a guard column of similar characteristics. The UV detector was set at 240 nm. A study to select adequate composition of the micellar mobile phase for the separation of these compounds in urine samples is performed. Maximum resolution was achieved with a 0.07 M sodium dodecylsulphate-0.3% propanol at pH 7.4 eluent. Limits of detection at 240 nm were ranged between 0.13 μg ml −1 for diallyl barbit…
Control of propranolol intake by direct chromatographic detection of alpha-naphthoxylactic acid in urine.
2002
A rapid chromatographic procedure with a C18 column, a mobile phase of 0.15 M sodium dodecyl sulfate (SDS)-10% (v/v) 1-propanol at pH 3 (0.01 M phosphate buffer), and fluorimetric detection, is reported for the control of propranolol (PPL) intake in urine samples, which are injected directly without any other treatment than filtration. The peak of PPL was only observed in samples taken a few hours after ingestion of the drug due to its extensive conjugation and metabolisation. The detection of several unconjugated PPL metabolites was therefore considered: desisopropylpropranolol (DIP), propranolol glycol (PPG), alpha-naphthoxylactic acid (NLT) and alpha-naphthoxyacetic acid (NAC). NLT showe…
Micellar liquid chromatography determination of rivaroxaban in plasma and urine. Validation and theoretical aspects.
2019
A Micellar Chromatographic method to determine rivaroxaban in plasma and urine has been developed. The samples were dissolved in the mobile phase (SDS 0.05 M – 1-propanol 12.5%, phosphate buffered at pH 7) and 20 μL directly injected, avoiding the extraction and purification steps. Using a C18 column and running under isocratic mode at 1 mL/min, analyte was eluted without interference from the matrix in <6.0 min. The detection absorbance wavelength was set to 250 nm. The procedure was validated by Food and Drug Administration guidelines in terms of: system suitability, calibration range (0.05–5 mg/L), linearity, sensitivity, robustness, carry-over effect, specificity, accuracy (−11.1 to 4.2…